The Honeywell motorised valve faults detailed above are likely to apply to most domestic Honeywell valves. Honeywell 2-port motorised zone valves (V4043H) are electrically quite simple. The powerhead contains the motor, which is used to drive the valve open, and an auxiliary switch or end switch. Honeywell 22mm zone valve operation (V4043H1056) Much of what we describe also applies to ACL Drayton motorised valves like the Drayton 2-port ZA5/679-2 22mm zone valve and the Drayton 3-port MA1/679 22mm mid-position valve. Iflo motorised valves and British Gas motorised valves have similar faults. It may also apply to the Tower VAL222MV motorised valve, the Siemens CZV222 motorised valve and the Flomasta 27900SX motorised valve.

In smaller properties there is usually one programmer which has two channels. One programmer channel controls the heating (radiators or underfloor) and the other programmer channel controls hot water. Where additional zone valves are used there will usually be another programmer or timer. Honeywell motorised valve construction There is, however, more information the lever can give us if we know what we’re looking for. The lever pushes the valve open against the return spring. The valve does not pull the lever over towards the open end as the valve opens. The V4073A 3-port valve never closes water flow through the valve completely. There is always an open pathway from port AB to port A or from port AB to port B or from port AB to both ports A and B at the same time. A programmer and room thermostat (stat) are used to control heating times and room air temperatures. The programmer and room stat may be combined into a single programmable room stat. If the powerhead was removed from the valve to make it easier to change the motor, it must now be re-attached to the valve. The power head cover can then be refitted and secured with the single screw. Make sure it sits squarely on the powerhead, with no wires pushing out from the sides.Sometimes a powerhead is able to drive the valve only part way open but not far enough for the auxiliary circuit end switch to close. This valve will then not be able to tell the boiler to fire. If the powerhead (actuator) can be safely removed from the valve body (see warning above about pre-1985 Honeywell valves) you can try to turn the spindle. You may need a tool unless you have strong fingers. You must also isolate the electrical supply before removing a Honeywell motorised valve powerhead. Drive spindle of a Honeywell motorised valve. It is accessed by removing the valve powerhead. Be warned, with Honeywell motorised valves made pre-1985 you have to drain down first to remove the powerhead!

Slide the blunt end of the motor sideways until the flange comes out from the tab holding it down. This can be a bit of a fiddle. The motor then comes free of the valve, held only by the two wires which connect it electrically. These two wires may be blue (in a Honeywell original Synchron motor) or orange (most replacement Synchron motors). As with most equipment, parts or tools, there are a few things you need to consider before buying a motorised valve, including ensuring that your heating system can use motorised valves.When the programmer and stat send a Live feed to the 2-port motorised brown wire, the motor drives the valve open to allow water to pass. When the valve is fully open, the end switch closes, allowing electrical current to pass from the grey wire to the orange wire and from there to the boiler Switched Live. Unless the boiler thermostat is already up to temperature, the boiler will now fire. This can cause the valve spindle to seize. It often becomes stiff to turn at first and the valve may give intermittent problems. Eventually, the spindle may become so stiff that the valve motor cannot turn it at all. When a V4073A mid-position valve is set up in a Y-Plan configuration and Hot Water is called for, power to the boiler is provided directly from the cylinder thermostat. The valve is not energised. Replacing a failed Synchron motor in a Honeywell motorised valve is quite straightforward, assuming you know how to work with mains electricity safely. Make sure you read the whole process through before starting! A normally-closed valve is closed when no power is being applied to it and needs electrical power to drive it open.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment