There are three widely used ways to test emergency lighting. To understand them it is necessary to understand first how an emergency light fitting is wired. Note that the remarks that follow apply to self-contained emergency fittings, not to central battery operated emergency fittings. A minimum duration of 3 hours should be used for emergency escape lighting if the premises are not evacuated immediately. The 3 hour time frame allows the fire brigade time to work in the event of a fire after all of the building’s occupants have been safely evacuated. How often should my emergency lighting system be tested? Yes if you are testing/servicing on the discharge test then no lights would be a problem for persons working in those areas and so this would need doing when unoccupied - so I can see the logic behind the key switches not shutting off power - but that would only be for green LEDs and not red LEDs that would be difficult to visually see - similar if 3 tube lighting is working and one of the tubes is the EL light you wouldn't know if that EL unit was working if the main lights are still being powered... As I understand it the EL light units that (should) have LEDs on them, the LEDs are illuminated when in normal 'charging' mode but go out when in EL mode? Records of all testing and maintenance carried out on the emergency lighting system, including dates, results, and any faults or issues identified.

The name of the person or organization responsible for the maintenance and testing of the emergency lighting system. First floor has a conference room, dining area, servery and kitchen with adjourning conveniences, 11 rooms (classroom or meeting/training rooms), 5 office rooms and 3 sets of conveniences. Sometimes there isn’t a test key switch. If not then you have to find the consumer unit and turn off the power to the whole circuit that controls the emergency lights. Hopefully it will be marked which one it is, but it could be more than one circuit.

Additional Combined Services

Test facilities often take the form of a fishtail key inserted into a specific switch, either near the main fuse board or relevant light switches. Additional Combined Services

It is worth noting that the duration of emergency lighting may vary depending on the specific application. For example, in areas where there is a higher risk to the safety of occupants, such as escape routes, the emergency lighting may need to remain illuminated for a longer period of time. This should be determined through a risk assessment and in accordance with the relevant regulations and standards. Any other relevant information, such as details of training provided to staff on the use of the emergency lighting system.Details of any repairs or replacements carried out on the emergency lighting system, including dates and the nature of the work carried out. The kind of emergency lighting system your building requires depends on the nature of your business. For example, the emergency lighting system is not always required to provide light at the same intensity as the mains (however, it should be bright enough for safe evacuation). By working with the qualified engineers at Voltix Services , system designs and the ideal testing regime are all part of our compliance services . Yes and no. If it is a small building and all the emergency lights are on one circuit, then yes, you have no choice. However if it is a large building then it would make sense to stagger the testing. This way the whole building would not be affected if there was a power cut, during the recharge time. Testing Central Battery Systems L PERM is the permanent live supply and must have no normal (manually operated) switch or sensor on it. However, a key-switch is permissible and will usually be installed on this circuit. L PERM has two functions: High risk task area lighting provides light for the safety of people involved in potentially dangerous processes. This lighting enables proper shut-down procedures to be followed for the safety of the operator and other occupants of a building.

Be very careful when touching anything inside the electrical consumer box, there is a danger of electrocution if something is wrong. If in doubt seek a qualified electrician ** What time of day should I test the emergency lights BS5266-1 states that emergency lighting should be regularly tested. How often should emergency lighting be tested?Carry out a full discharge test of the emergency lights to ensure that they remain illuminated for the required duration (usually 1-3 hours). Simple system would be you switch the main lights on as normal, then operate the test key switch which simulates a power cut - so you can visually see the EL works.