As a general rule, you must have a call point within 30 metres of any location within a building and there should be at least one on each storey. High-risk areas may need additional call points installed. Each use of an emergency account should be reviewed. The use of an emergency account may be valid, or it might indicate a malicious act. Unacceptable use needs to be recorded and acted upon. Frequent use may indicate problems with the normal user authentication mechanism. This regular monitoring of pre–staged emergency accounts should also include exercising some of them to ensure that they do work, and that their use can be detected. This is similar to testing fire alarms, to be sure that they will work in a real emergency. Cleaning Up After Account Usage

Manual call points can have more than one function. They come in three colours: white, green and red. The different colours indicate the function of each individual call point: The glass works to protect the fire alarm from accidental activations. However, these alarms are activated by a pressure switch, which is why glass is incorporated into the trigger. When the glass fails or breaks, the switch will be triggered, the signal will be sent to the alarm panel, and the sound will go off. No User Account (e.g. a clinician from another organization or a new clinician is assisting a facility during an emergency) There’s always something new you can learn to improve your fire safety knowledge and today we’ll look at yet another key element of your fire detection system – the manual call points (MCP) used to activate your fire alarm. From what they actually do and where to find them to using and testing them correctly – here’s everything you need to know about fire alarm call points.Designed to prevent accidental and malicious false fire alarms, SSP’s Direct range of call point covers, break glass covers and push button covers are ideal for use in schools, colleges, nursing and care homes, hospitals and shopping centres.

Altering the environment – you might be tempted to put headphones in whilst the testing is being carried out, unfortunately, you shouldn’t do this.Green manual call points: Those are located next to an exit and they are used to manually release a door while trying to evacuate the building in the event of an emergency Whether other work is to be done at the same time. If so then consultation with other contractors may be required. In the obscuring type the smoke interferes with a light beam between a light source and photo cell, the variation in photo cell output being used to initiate an alarm. This type of detection can be used to protect large areas with the source and photo cell positioned some distance apart. Light scattering

In addition to government legislation, byelaws and local policy documents exist, created by local authorities at both district and county level, demanding the installation of fire alarm systems. These vary from area to area and advice must be sought from the appropriate local authority on any regulations in force. British Standards Relating to Fire AlarmsUsually, the user will break the glass and press the emergency button centred in the middle of the unit. This will then activate a centralised alarm system to alert building wide that there is an emergency. Voice alarm systems should be tested weekly in accordance with BS5839 Part 8. If the system is connected to an Alarm Receiving Centre (ARC) for calling the fire brigade, it is very important that the ARC is notified before testing commences and when it is complete Architects have their own abbreviations, symbols and drawing conventions to enable all persons in their profession to understand drawings produced for their use. Drawing conventions are subject to BS 1192: 2007 Collaborative production of architectural, engineering and construction information. The current fire protection drawings standard is BS 1635: 1990 Recommendations for graphic symbols and abbreviations for fire protection drawings . However, many fire engineers do not use the current standard and the symbols below are used. Many of the following symbols are used by the British Fire Service and most probably based on BS 1635: 1970. When marking up a drawing you can use symbols of your own choice, providing you create a legend showing what each symbol represents. Depending on the reason for the drawing, Means of Escape for instance, you may use the symbol to show an area to be covered, in accordance with the current British Standard, not the exact location and the symbols below would be acceptable. Other times, an emergency lighting engineer for instance would require to show the exact location of a luminaire to enable the electrician to fit it in accordance with the current British Standard. In this situation BS 1635: 1990 would be more useful for the purpose. KEY TO PLAN SYMBOLS AND ABBREVIATIONS

Call point test keys are used to test your fire alarm is working correctly, they’re crucial for fire alarm systems Why Should I Test My Call Points? Fixed temperature which will operate when it is exposed to a pre-determined temperature. Normally fixed temperature detectors employ a fusible alloy element which must be replaced after the detector has operated. Different temperature rated elements are available to take account of varying ambient air temperatures.Fire detection and alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems Tags: alarm panel servicing frequencies BS 5839-1:2013 bs5839 BS5839 part 1 2017 BS5839 part 6 2013 BS5839 pt 6:2013 BS5839 pt1:2017 fire alarm panel maintenance how to install fire alarm panel maintaining a fire alarm system servicing of fire alarm panels servicing of fire alarm systems It is not the object of this note to consider the details of different circuit types or to discuss their relative merits. Types of Fire Alarm Systems