As we have mentioned above, when running down a wall to a power supply unit such as this the cable will need to run vertically down in a straight line to comply with regulations. Once this is done, a minor works certificate is then issued to prove the installation has been carried out correctly. However if you are installing in an upstairs then you may be able to locate a suitable supply in the loft. This is often the easiest route as everything should be much more accessible. In the UK there are very strict rules on who can and cannot do certain electrical jobs. This is mainly due to the fact that, as we all know, electricity is extremely dangerous and when working on or around it, it is essential that you know what you are doing.

Masterplug 3 Pin Fused Shaver Socket Adaptor - White 250V

If either of the above are ignored, if any issues occur and you cannot produce a certificate for the works then there is a good chance that your home insurance will be invalid, so it certainly isn’t worth the risk.The cable was then secured in place using UPVC capping to not only hold it but also protect it from any damage that might from any potential future work. There are many types of adaptors on the market and knowing what is suitable for what purpose is important to get a safe and reliable result. Wall chased out and cable placed in chase and protective UPVC pipe Step 3 – Install Fused Connection Unit (FCU) visitor adaptors (e.g. http://www.roamingfox.co.uk/UK-Visitor-Travel-Adapter-pr-16228.html ). Theese have a higher current rating than shaver adaptors and can be used with some earthed plug types. However THEY WILL NOT PROVIDE AN EARTH TO GERMAN/DUTCH/FRENCH plugs. shaver adaptors: (e.g. http://www.maplin.co.uk/Module.aspx?ModuleNo=1186&DOY=31m3#features) theese are designed for shavers and can also be used for other very small <1A appliances that do not require earthing and come with a two pin europlug (a relatively thin plug with two thin flexible pins). They are NOT suitable for either applicances that require higher currents or those that require earthing

Wilko 1 Amp Fused Shaver Adaptor | Wilko - Wilko Site Wilko 1 Amp Fused Shaver Adaptor | Wilko - Wilko Site

As previously mentioned, if you are sing a lighting circuit make sure it’s RCD protected. If it isn’t then you can’t use it. The cable is then normally capped (covered with a protective UPVC capping) or run through some UPVC trunking/pipe to protect it and hold it in place.Zone 2 – the area beyond zones 0 and 1, 0.6m horizontally and up to 2.25m vertically. Zone 2 also includes any recessed window with a sill next to the bath and also around the wash basin In this example here we are using an existing lighting circuit so a 1mm twin and earth cable is run out from the top of the ceiling rose, down through the ceiling and down a chase that was cut into the wall. Once all the wires have been connected, the face plate is then screwed on to the pattress box, fixing it in place. Once in place the cable was then tested to ensure there were no breaks etc. This is a necessary step as once the cable is filled over it’s a nightmare to have to dig it all out if it’s damaged.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment